Description
Help improve the environment with GloveOn Avalon biodegradable gloves. Designed to break down normal nitrile gloves in landfill settings, these gloves will take years rather than decades to completely biodegrade. Our unique formulation maintains the high levels of strength and flexibility you’d expect in a nitrile glove, while only allowing the biodegradation process to start once in landfill conditions. Feel confident that GloveOn Avalon will give you the protection you need and help you do your bit for the environment.
REORDER CODE | SIZE |
---|---|
BDG33XS | X-Small |
BDG33SS | Small |
BDG33MM | Medium |
BDG33LL | Large |
BDG33XL | X-Large |
MANUFACTURING ACCREDITATIONS | |
---|---|
Accreditations | ISO 9001 ISO 13485 EN ISO 13485 |
CHEMOTHERAPY DRUGS AND CONCENTRATION (TESTED FOR RESISTANCE TO PERMEATION BY CHEMOTHERAPY DRUGS AS PER ASTM D6978-05-TEST REPORT PN 145460) |
MINIMUM BREAKTHROUGH DETECTION TIME (MINUTES) |
---|---|
Carmustine (BCNU), 3.3mg/ml (3,300ppm) | 22.2 |
Cisplatin, 1.0mg/ml (1,000ppm) | >240 |
Cyclophosphamide (Cytoxan), 20.0mg/ml (20,000ppm) | >240 |
Dacarbazine (DTIC), 10.0mg/ml (10,000ppm) | >240 |
Doxorubicin Hydrochloride, 2.0mg/ml (2,000ppm) | >240 |
Etoposide (Toposar), 20.0mg/ml (20,000ppm) | >240 |
Fluorouracil, 50.0mg/ml (50,000ppm) | >240 |
Methotrexate, 25.0mg/ml (25,000ppm) | >240 |
Mitomycin C, 0.5mg/ml (500ppm) | >240 |
Paclitaxel (Taxol), 6.0mg/ml (6,000ppm) | >240 |
Thiotepa, 10.0mg/ml (10,000ppm) | 66.1 |
Vincristine Sulfate, 1.0mg/ml (1,000ppm) | >240 |
WARNING: Carmustine and Thiotepa, at the tested concentration, degraded a Celeste nitrile glove at 22.2 minutes and 66.1 minutes respectively. The safe use of gloves in chemotherapy treatment is solely the decision of clinicians authorised to make such a decision. |